Proyecto de tratamiento de agua potable de 57,6 m³/h en Rumanía
Resumen del proyecto
| Artículo |
Detalles |
| Nombre del proyecto |
Proyecto de tratamiento de agua potable |
| Ubicación |
Motatei, Romania |
| Año |
May 2019 |
| Water Source |
Deep well water from 6 wells |
| Total Capacity |
57.6m³/h |
| System Configuration |
Carbon Filter + Ion Exchange / Carbon Filter + RO |
| Container Type |
40HQ FLC |
| Control Method |
Remote control |
Antecedentes del proyecto
The raw water came from six deep wells in Romania. Several water quality indicators exceeded the required limits, including ammonia, nitrate, E. coli, total bacterial count, iron, and manganese. Among these issues, nitrate was the most critical, while ammonia, iron, and manganese were slightly above standard limits.
To meet drinking water requirements, the project adopted a combined treatment process. Disinfection and activated carbon filtration were used to handle microbial indicators and slightly excessive ammonia, iron, and manganese. RO treatment was applied to reduce nitrate levels, while ion exchange water and RO permeate were blended to achieve the required final water quality.
Solución de tratamiento
The project uses two parallel treatment lines:
- Carbon Filter + Ion Exchange System: 28.8m³/h
- Carbon Filter + RO System: 28.8m³/h
The RO permeate and ion exchange product water are mixed to produce drinking water. The system design supports stable output while maintaining suitable nitrate and hardness levels in the final blended water.

Flujo de procesos
Ion Exchange Line
Raw Water Tank → Raw Water Pump → Activated Carbon Filter → Ion Exchanger → Product Water Tank
RO Line
Raw Water Pump → Activated Carbon Filter → Security Filter → High Pressure Pump → RO Unit → Product Water Tank
Sistemas de apoyo
- Antiscalant dosing system
- Chemical cleaning system
- Disinfection dosing system
- Remote control system
Principales resultados
- Total water production capacity: 57.6m³/h
- RO system product water nitrate: <12.15mg/L
- RO system hardness: <2.8mg/L as CaO
- Final blended water nitrate: <28.8mg/L
- Final blended water hardness: >6.85mg/L
- Final water quality meets drinking water requirements

Proyectos destacados
- Containerized integrated design in one 40HQ FLC
- Combination of RO and ion exchange treatment
- Blended water production for drinking water use
- Remote control for easier operation

Aplicaciones
- Well water drinking treatment
- Groundwater purification
- Municipal and decentralized water supply
- Containerized drinking water systems