{"id":1128,"date":"2026-04-27T16:04:38","date_gmt":"2026-04-27T08:04:38","guid":{"rendered":"https:\/\/banott.com\/?post_type=cases&#038;p=1128"},"modified":"2026-04-27T16:04:38","modified_gmt":"2026-04-27T08:04:38","slug":"68000m%c2%b3-d-municipal-wastewater-uf-system-project-in-the-philippines","status":"publish","type":"cases","link":"https:\/\/banott.com\/fr\/cases\/68000m%c2%b3-d-municipal-wastewater-uf-system-project-in-the-philippines\/","title":{"rendered":"Projet de syst\u00e8me d'UF pour les eaux us\u00e9es municipales d'une capacit\u00e9 de 68 000 m\u00b3\/d aux Philippines"},"content":{"rendered":"<h2>Aper\u00e7u du projet<\/h2>\n<table>\n<thead>\n<tr>\n<th>Objet<\/th>\n<th>D\u00e9tails<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Nom du projet<\/td>\n<td>Projet de syst\u00e8me de traitement des eaux us\u00e9es municipales<\/td>\n<\/tr>\n<tr>\n<td>Localisation<\/td>\n<td>Philippines<\/td>\n<\/tr>\n<tr>\n<td>Ann\u00e9e<\/td>\n<td>Mai 2017<\/td>\n<\/tr>\n<tr>\n<td>Application<\/td>\n<td>Traitement des eaux us\u00e9es municipales<\/td>\n<\/tr>\n<tr>\n<td>Capacit\u00e9 de production d'UF<\/td>\n<td>68 000m\u00b3\/d \/ 2 833m\u00b3\/h<\/td>\n<\/tr>\n<tr>\n<td>Quantit\u00e9 du syst\u00e8me<\/td>\n<td>12 unit\u00e9s UF<\/td>\n<\/tr>\n<tr>\n<td>Capacit\u00e9 par unit\u00e9<\/td>\n<td>240m\u00b3\/h<\/td>\n<\/tr>\n<tr>\n<td>Taux de r\u00e9cup\u00e9ration de l'UF<\/td>\n<td>90%<\/td>\n<\/tr>\n<tr>\n<td>Taille de l'unit\u00e9 unique<\/td>\n<td>7m \u00d7 3m \u00d7 3.3m<\/td>\n<\/tr>\n<tr>\n<td>R\u00f4le du processus<\/td>\n<td>Pr\u00e9traitement UF avant RO<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Contexte du projet<\/h2>\n<p>Ce projet a \u00e9t\u00e9 con\u00e7u pour une grande application de traitement des eaux us\u00e9es domestiques municipales. La qualit\u00e9 de l'eau entrante \u00e9tait relativement stable, avec une DBO &lt; 20mg\/L et des MES &lt; 30mg\/L. Apr\u00e8s le traitement UF, l&#039;eau devait r\u00e9pondre aux conditions de l&#039;eau d&#039;alimentation RO.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1130\" src=\"http:\/\/banott.com\/wp-content\/uploads\/2026\/04\/Municipal-Wastewater-UF-System-Project-in-the-Philippines-3.webp\" alt=\"Municipal Wastewater UF System Project in the Philippines (3)\" width=\"534\" height=\"330\" srcset=\"https:\/\/banott.com\/wp-content\/uploads\/2026\/04\/Municipal-Wastewater-UF-System-Project-in-the-Philippines-3.webp 534w, https:\/\/banott.com\/wp-content\/uploads\/2026\/04\/Municipal-Wastewater-UF-System-Project-in-the-Philippines-3-300x185.webp 300w, https:\/\/banott.com\/wp-content\/uploads\/2026\/04\/Municipal-Wastewater-UF-System-Project-in-the-Philippines-3-18x12.webp 18w\" sizes=\"auto, (max-width: 534px) 100vw, 534px\" \/><\/p>\n<h2>Solution de traitement<\/h2>\n<p>Le syst\u00e8me d'UF a \u00e9t\u00e9 con\u00e7u comme la principale section de filtration membranaire du projet. Le pr\u00e9traitement avant l'UF et le traitement avanc\u00e9 apr\u00e8s l'UF ont \u00e9t\u00e9 pris en charge par l'entrepreneur du projet, tandis que la section UF a \u00e9t\u00e9 con\u00e7ue pour fournir des performances de filtration stables avant l'\u00e9tape d'OI.<\/p>\n<p>Le syst\u00e8me comprend 12 unit\u00e9s d'UF, chacune ayant une capacit\u00e9 de production de 240m\u00b3\/h. La production totale d'UF atteint 68 000m\u00b3\/j, avec un taux de r\u00e9cup\u00e9ration de 90%. La production totale d'UF atteint 68 000 m\u00b3\/j, avec un taux de r\u00e9cup\u00e9ration de l'UF de 90%.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1131\" src=\"http:\/\/banott.com\/wp-content\/uploads\/2026\/04\/Municipal-Wastewater-UF-System-Project-in-the-Philippines-4.webp\" alt=\"Municipal Wastewater UF System Project in the Philippines (3)\" width=\"534\" height=\"330\" srcset=\"https:\/\/banott.com\/wp-content\/uploads\/2026\/04\/Municipal-Wastewater-UF-System-Project-in-the-Philippines-4.webp 534w, https:\/\/banott.com\/wp-content\/uploads\/2026\/04\/Municipal-Wastewater-UF-System-Project-in-the-Philippines-4-300x185.webp 300w, https:\/\/banott.com\/wp-content\/uploads\/2026\/04\/Municipal-Wastewater-UF-System-Project-in-the-Philippines-4-18x12.webp 18w\" sizes=\"auto, (max-width: 534px) 100vw, 534px\" \/><\/p>\n<h2>D\u00e9roulement du processus<\/h2>\n<p>R\u00e9servoir d'eau brute \u2192 Pompe d'eau brute \u2192 Pr\u00e9traitement \u2192 Syst\u00e8me UF \u2192 R\u00e9servoir d'eau UF<\/p>\n<h2>Syst\u00e8mes de soutien<\/h2>\n<ul>\n<li>Syst\u00e8me de dosage \u00e0 contre-courant<\/li>\n<li>Syst\u00e8me de nettoyage UF<\/li>\n<\/ul>\n<h2>Principaux r\u00e9sultats<\/h2>\n<ul>\n<li>Capacit\u00e9 de production d'UF : 68 000 m\u00b3\/j<\/li>\n<li>Capacit\u00e9 d'une seule unit\u00e9 : 240m\u00b3\/h<\/li>\n<li>Configuration totale du syst\u00e8me : 12 unit\u00e9s UF<\/li>\n<li>Taux de r\u00e9cup\u00e9ration de l'UF : 90%<\/li>\n<li>Eau trait\u00e9e adapt\u00e9e aux besoins d'alimentation de l'OI<\/li>\n<li>Capacit\u00e9 de pr\u00e9traitement des eaux us\u00e9es municipales \u00e0 grande \u00e9chelle<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1133\" src=\"http:\/\/banott.com\/wp-content\/uploads\/2026\/04\/Municipal-Wastewater-UF-System-Project-in-the-Philippines-2.webp\" alt=\"Municipal Wastewater UF System Project in the Philippines (3)\" width=\"534\" height=\"330\" srcset=\"https:\/\/banott.com\/wp-content\/uploads\/2026\/04\/Municipal-Wastewater-UF-System-Project-in-the-Philippines-2.webp 534w, https:\/\/banott.com\/wp-content\/uploads\/2026\/04\/Municipal-Wastewater-UF-System-Project-in-the-Philippines-2-300x185.webp 300w, https:\/\/banott.com\/wp-content\/uploads\/2026\/04\/Municipal-Wastewater-UF-System-Project-in-the-Philippines-2-18x12.webp 18w\" sizes=\"auto, (max-width: 534px) 100vw, 534px\" \/><\/p>\n<h2>Points forts du projet<\/h2>\n<ul>\n<li>Conception de syst\u00e8mes d'UF \u00e0 grande \u00e9chelle<\/li>\n<li>Solution de pr\u00e9traitement pour l'eau d'alimentation RO<\/li>\n<li>90% Taux de r\u00e9cup\u00e9ration de l'UF<\/li>\n<li>Configuration modulaire avec 12 unit\u00e9s UF<\/li>\n<li>Convient aux projets de traitement des eaux us\u00e9es municipales<\/li>\n<\/ul>\n<h2>Applications<\/h2>\n<ul>\n<li>Traitement des eaux us\u00e9es municipales<\/li>\n<li>Pr\u00e9traitement UF avant RO<\/li>\n<li>Projets de r\u00e9utilisation de l'eau \u00e0 grande \u00e9chelle<\/li>\n<li>Modernisation des syst\u00e8mes de filtration membranaire<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1134\" src=\"http:\/\/banott.com\/wp-content\/uploads\/2026\/04\/Municipal-Wastewater-UF-System-Project-in-the-Philippines-1.webp\" alt=\"Municipal Wastewater UF System Project in the Philippines (3)\" width=\"534\" height=\"330\" srcset=\"https:\/\/banott.com\/wp-content\/uploads\/2026\/04\/Municipal-Wastewater-UF-System-Project-in-the-Philippines-1.webp 534w, https:\/\/banott.com\/wp-content\/uploads\/2026\/04\/Municipal-Wastewater-UF-System-Project-in-the-Philippines-1-300x185.webp 300w, https:\/\/banott.com\/wp-content\/uploads\/2026\/04\/Municipal-Wastewater-UF-System-Project-in-the-Philippines-1-18x12.webp 18w\" sizes=\"auto, (max-width: 534px) 100vw, 534px\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>A large-scale municipal wastewater treatment project in the Philippines adopted a UF system as pretreatment before RO. The UF system was designed with a total water production capacity of 68,000m\u00b3\/d, helping the treated water meet RO feed water requirements.<\/p>","protected":false},"featured_media":1130,"comment_status":"closed","ping_status":"closed","template":"","case_cat":[21,24],"class_list":["post-1128","cases","type-cases","status-publish","has-post-thumbnail","hentry","case_cat-uf-system-applications","case_cat-wastewater-treatment"],"acf":[],"_links":{"self":[{"href":"https:\/\/banott.com\/fr\/wp-json\/wp\/v2\/cases\/1128","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/banott.com\/fr\/wp-json\/wp\/v2\/cases"}],"about":[{"href":"https:\/\/banott.com\/fr\/wp-json\/wp\/v2\/types\/cases"}],"replies":[{"embeddable":true,"href":"https:\/\/banott.com\/fr\/wp-json\/wp\/v2\/comments?post=1128"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/banott.com\/fr\/wp-json\/wp\/v2\/media\/1130"}],"wp:attachment":[{"href":"https:\/\/banott.com\/fr\/wp-json\/wp\/v2\/media?parent=1128"}],"wp:term":[{"taxonomy":"case_cat","embeddable":true,"href":"https:\/\/banott.com\/fr\/wp-json\/wp\/v2\/case_cat?post=1128"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}